16A1 BM - Tender X-ray Absorption, Diffraction

The optical layout of beamline BL16A


Optical Parameters
Monochromator DCM, Si(111), InSb(111), Beryl(1010)
Mirrors CM and FM
Method of Focusing 1.4 m toroidal mirror
Beam Size on Sample or Detector0.5 mm × 1 mm
Characteristics of DCM Tender X-ray Beamline
E = 1.5 GeV, I = 300 mA, lc = 8.89 Å, P = 3.45 W/mrad
Energy Range900 eV ~ 8 keV
Scanning Range 12˚ ~ 72˚
Horizontal Acceptance Angle6 mrad
Mono. Crystal Beryl (1010)InSb(111)Si (111)
2d (Å) 15.92 7.48 6.27
Energy Range (keV) 0.9 ~ 2 1.75 ~ 42.1 ~ 6
Scanning Angle 59.9˚ ~ 22.9˚72.0˚ ~ 24.5˚70.2˚ ~ 19.2˚
Resolving Power (E/ΔE) 2500 3000 7000
Flux (photons/sec) 3 × 1011
Spot Size (H × V) < 0.5 mm × 1.0 mm
Sample Position18.20 mm

Performance

 

 

Find a Beamline

16A1 Home

Specifications

Endstations

BL Schedule

Optical Layout

Gallery


 Contacts

Endstation

+886-3-578-0281 Ext. 1161

BL Spokesperson

Chan, Ting-Shan (詹丁山)
chan.ts@nsrrc.org.tw
+886-3-578-0281 Ext. 7111

BL Manager/Local Contact

Li, Ruo-Yang (李若暘)
li.ry@nsrrc.org.tw
+886-3-578-0281 Ext.7127


Techniques

  • X-ray Absorption Spectroscopy (XAS)
  • X-ray Absorption Fine Structures Spectroscopy (XAFS)

Disciplines

  • Materials science
  • Environment and energy related research
  • Physics
  • Geoscience
  • Chemistry
  • Condensed matter physics
  • Functional materials
  • Energy materials

General Information

  • Source: BM
  • Energy Range: 1~8 keV
  • Focused Spot Size: 0.25 × 0.16 mm
  • Status: Operational