  1. Please describe the main function and the components of the Michaelson interferometer in an FTIR spectrometer. 
  2. Calculate the displacement for the moving mirror in a Michaelson interferometer for resolving the 0.1 cm-1 difference between the adjacent narrow spectral peaks. And explain why one wavenumber difference is the criteria to define spectral resolution as resolving adjacent narrow spectral peaks?
  3. (a) Explain the optical purpose for the design of a dual aperture in a confocal infrared microscope. 

    (b) Calculate the diffraction-limit wavelength for the incident radiation in the reflection measurement of confocal FT-IR microscopy and the numerical aperture (N.A.) of an IR objective and a diameter of the confocal aperture is 0.65 and 8.0 um, respectively. (P.S. Check the significant figures after completing the calculation.) 

  4. Briefly explain why a periodical change of dipole moment is the criteria for vibration transition for a molecule.
  5. How to define the spectral resolution of FTIR spectrometer and why?
  6. Give the idea of why NanoIR can deliver a nano-scale lateral resolution

試卷下載

FTIR操作手冊下載

1.Thermo紅外光譜顯微術光譜儀   ATR-FTIR  SERIES

2.Bruker全場式紅外光譜儀   簡易版  SOP 雷射聚焦系統

3.KBr 打片器操作

4.ATR-FTIR

5.FTIR樣品處理及量測

6.鹽片介紹

數據處理

1.Peak resolve 

2. Profile Setup

3.Peak Assign Amide I&II

參考網頁

Find a Beamline

14A1 Home

Specifications

Performance

Techniques

Front End & Endstations

Training Course

Staff

Other BL Info

BL Schedule

NEWS

Gallery


 Contacts

Endstation

+886-3-578-0281 Ext. 1141

BL Spokesperson

Lee, Yao-Chang (李耀昌)
yclee@nsrrc.org.tw
+886-3-578-0281 Ext. 7333

BL Manager/Local Contact

Huang, Pei-Yu (黃佩瑜)
pyhuang@nsrrc.org.tw
+886-3-578-0281 Ext. 7329


Techniques

  • IR/Visible/UV/VUV Spectroscopy

Disciplines

  • Molecular science
  • Biomaterials
  • Biochemistry
  • Materials science
  • Chemistry
  • Polymer and soft matter
  • Bio-medical imaging

General Information

  • Source: BM
  • Energy Range: 0.5-0.05eV
  • Focused Spot Size: 13 x 10 μm²
  • Status: Operational







National Synchrotron Radiation Research Center

101 Hsin-Ann Road, Hsinchu Science Park, Hsinchu, Taiwan 30076

+886-3-578-0281